RSS Feed
Knowledgebase : Fleet Broadband > Terminal
 


Multivoice problem: Multi-voice control connection errorFrom Event log and IP handset: 08079-0  Terminal  WARNING  Multi-voice control connection errorFrom diagnostic report: [08079 0 1] (WARNING ON 1) EV_BDU_MV_CONTROL_PDP_ERROR (33)Possible soultion. 1:...
The Warning "08040-0 Terminal WARNING Excessive writes to the flash memory" is normal caused by a constant restart of a data connection. If the system is set to 'automatic activation' and the attach is rejected, the a new attempt is made within...
Quiestion: If a Fleet Broadband terminal that is set up with Auto Activate for a data connection and it loses that data connection.  How can the data session be activated again? Using launch pad we able to open the session agian but can it be restarted ...
Question:Is possible to have a DYNAMIC DHCP pool range on the Fleet BB and also STATIC IP address, that will not be in the DHCP range.  For example setting the DHCP Pool Range of 192.168.0.100 to 200 and also have STATIC IP Addresses attached to the devic...
08063 0 1  [08063 0 1  ] (WARNING ON      1) EV_BDU_SAFETY_HANDSET_MISSING08064 0 1  [08064 0 1  ] (WARNING ON      1) EV_BDU_SAFETY_ALARMPANEL_MISSING----------------------------------------Enabling the CS safety in the FBB WEB MMI will cause below if ...
Make a Telnet session to the terminal (192.168.0.1)Username: adminPassword: 1234Welcome to the Thrane & Thrane shelltelnet:/$telnet:/$ dns_relay      "to see state of the dns_relay"DNS relay: disabledtelnet:/$ help dns_relay  "to see th...
Below at cmd's can be used to get position information from the terminal. at_igps?at_itnmea?  at_itnmea= rmc at_itnmea=gga -----------------------------------------------------------------------------------------  at_igps? _IGPS: 55.7941,1...
When starting the Launchpad the error: "Operation not allowed; Error processing request: AT_ISGLUSER=1" The Launchpad is a 'single user' application. So to use it together with a FBB, no entries in the "Network classification" is all...
We have created and sent to the vessel of one of our customers a configuration file.We have been informed that during the loading procedure they receive an error message: loading failed. Could it be a version issue? The terminal from which we have created...
ID 03502-0 - Terminal Error - 2-Wire calibration failure. 2-wire calibration failure is normal caused by on of the devices connected to the RJ11's is off hook. 1: check that the RJ11 devices is on hook. Reboot 2: if alarm still is present disconne...
Subnet that is not to be used with the FBB and Explorer terminals. The FBB and Explorer terminal is using different IP subnet for USB - Bluetooth - Network User Group. This subnet must not be used as source or destination networks. Internal routing tabl...
SIM lock to inserted sim fails. This is a bug in the personalization module, where it reads data from a chunk after it has been freed. This problem is present in the sw releases: FBB 500-250 1.09, E727 1.09, E300-500 3.00, E527, 3.00, 3.01, 3.02,  E700...
Knowledge base – Problems/solutionsDate: July - 2008  Product Name & Type:Product name: Sailor FleetBroadband 500, Sailor FleetBroadband 250, FBB 500, FBB 250, Explorer 727, EXP 727. T&T type number: TT-3740A, TT-3742A, TT-3722A. Hardware ...
Knowledge base – Problems/solutionsDate: February - 2008  Product Name & Type:Product name: Sailor Fleet Broadband 500 and Sailor Fleet Broadband 250. T&T type number: TT-3740A and TT-3742A. Software version affected: All SW versions befo...
Help Desk Software by Kayako Fusion