ADU(6)
SW(1)


 Power Input :Connector: Mixed D-Sub 7W2Nominal 12/24 VDC (10.5 - 32 V DC; 14 A - 5.5 A)Max. source impedance: 85 mW at 12 V, 500 mW at 24 VMaximum 20 A at 24 V, 5 ms (start up) "idle consumption“ (No additional equipment connected. track...
Cause codes from network. (Call log / Diagnostic report)Cause No. 1 "unassigned (unallocated) number" (UMTS specific cause values for call control)This cause indicates that the destination requested by the mobile station cannot be reached becaus...
User authentication failed We have seen some cases where data connections fails with: Cause 29, (0x1d), User authentication failed Most likely caused by wrong 'APN' user name or password. In some cases, the browser used for configuration, will 'remember'...
Antenna image is missing in antenna terminal Upload newest software version to the terminal. Problem has been seen when connection a different type of antenna to the terminal. (terminal is containing antenna software for different antenna types, and it h...
Overall C/No for Fleet broadband and Explorer terminals. 'Pointing mode' (E300/500/700)(Global beam-F80T1Q)= Min. 42 db 'Ready mode' all terminals (regional beam-F80T1X)= Min. 54,5 db 'Data active mode' all terminals (spot beam-F80T45X)= Min. 62,5 - reco...
Knowledge base – Setting-up / Configuration procedure Date: December - 2009  Product Name & Type:Product name: FleetBroadband500, FleetBroadband250, FleetBroadband150, FleetBroadband, FBB, FB T&T type number: TT-3740A, TT-3742A, TT-374...
Cause: 213249 (0x34101) - MM Unspecified Below 20 degrees of elevation the 3.1 kHz service are not supported.