Knowledgebase : Fleet > Operation
 


Subject: The MES originated 9.6K Fax service problem that has been seen on all three types of Fleet (Sailor Fleet77, Sailor Fleet55 and Sailor Fleet33) in some Ocean Regions and by some LES’ has now been identified. The LES’ affected has been identified t...
TT-3680F Power SupplyAs it has been recognized several times, the supply power to the Fleet77/55 has often been too weak.Thrane & Thrane has the following power specifications for the systems:The Fleet77 has the following power requirements:Input powe...
External power supply for BDUThe internal Power Supply Unit of the BDU has been designed as a +24 VDC, +30% / -10%, supply giving the input limit to be 21.6 - 32.2 VDC.On earlier BDU, a label was indicating that the input power to the Fleet77 should be 18...
Replacing an existing Inmarsat-A system with a Fleet77When an Inmarsat-A system has to be replaced with a Fleet77, following considerations should be taken:  The antenna platform can most likely be re-used, however it might be necessary to elevate it for ...